SIMPLEX STRAINERS
Challenge & Creation based on Experience and Technology
WATER STRAINER FOR CASTING
-
Specifications
Dimension Table Stress analysis code ASME Section VIII Division 1. Connection flange JIS B 2210, ANSI B 16.5, DIN, etc. Materials
- Body
- Filter
- Packing
Carbon Steel, Stainless Steel, Bronze, etc.
Carbon Steel, Stainless Steel, Monel, Titanium, etc.
N.B.R, E. P. D. M, T.T.F.E, Viton, etc.Filter Φ2 ~ Φ12 Mesh #2 ~ #100 / 11100 ~ 140 micron Lifting Ring, Yoke, Eye bolt Cover bolting Yoke, Bolt Vent / Drain type Screw, Flange, Valve, etc. Coating Tar Epoxy, Tar Free Epoxy, Hot Dipped Galv, etc. Liquid name Water, etc. General
Water strainers for casting available with bolted or quick release yoked cover. Yoke cover units are ideally suited for applications where frequent clean-out of the filter is expected. Having a spare, clean filter on hand will greatly reduce the cleaning time, and differential pressure gauges, with alarms, can be supplied to get the maximum on-stream time between cleaning cycles.Dimension Table
Dimension Table Nominal dia L L1 H1 H OH DRAIN/VENT
PLUGNet
Weight(kg)25A 170 85 75 180 213 M16x2P 6 32A 190 95 85 215 250 M16x2P 8.5 40A 190 95 85 215 250 M16x2P 9 50A 200 100 100 240 291 M16x2P 11 65A 250 125 135 305 376 M20x1.5P 19 80A 270 135 152 340 432 M20x1.5P 24 100A 320 160 185 400 521 M20x1.5P 36 -
Specifications
Dimension Table Stress analysis code ASME Section VIII Division 1. Connection flange JIS B 2210, ANSI B 16.5, DIN, etc. Materials
- Body
- Filter
- Packing
Carbon Steel, Stainless Steel, Bronze, etc.
Carbon Steel, Stainless Steel, Monel, Titanium, etc.
N.B.R, E.P.D.M, P.T.F.E, Viton, etc.Filter Φ2 ~ Φ12 Mesh #2 ~ #100 / 11100 ~ 140 micron Lifting Lug, Eye bolt, etc. Cover bolting Hinge, Stud, Hexagon, etc. Vent / Drain type Screw, Flange, Valve, etc. Coating Tar Free Epoxy, Hot Dipped Galv, etc. Liquid name Water, etc. General
Water strainers for casting are available with bolted or quick release hinge bolted cover. Hinge bolted cover units are ideally suited for applications. Where frequent clean-out of the filter is expected.
Having a spare, clean filter on hand will greatly reduce the cleaning time, and differential pressure gauges, with alarms, can be supplied to get the maximum on-stream time between cleaning cycles.Dimension Table
Dimension Table Nominal dia L L1 L2 H1 H OH MOUNTING LEG DRAIN/VENT
PLUGNet
Weight(kg)P1 P2 d1 125A 400 200 30 235 485 672 260 80 Ø19 M24x2P 64 150A 460 230 35 290 575 809 310 90 Ø19 M24x2P 91 200A 550 275 50 350 665 1010 380 100 Ø23 M24x2P 158 250A 680 340 60 450 825 1254 480 140 Ø25 M24x2P 265 300A 760 380 70 515 920 1434 540 160 Ø25 M24x2P 334 350A 820 410 75 575 1030 1634 590 180 Ø25 M24x2P 457 400A 880 440 80 645 1135 1823 650 200 Ø25 M24x2P 615